Description
Description

The assembly of NORMACLAMP® GBS is easily completed by means of either manual, pneumatic or electric standard tools
Materials
W1* |
W2 |
W3 |
W4 |
W5 |
x |
x |
 |
X |
X |
*No Chromium VI used for surface treatment |

Band Tension
The results of numerous test sequences proved that NORMACLAMP® GBS are superior to comparable competitive products:

Torques
The results of numerous test sequences proved that NORMACLAMP® GBS are superior to comparable competitive products:
Bandwidth
|
Failure Torque (Min. value ) |
Recommended tightening torque
|
W1
|
W2
|
W4
|
W5
|
18 |
15 Nm |
15 Nm
|
15 Nm
|
15 Nm
|
8 Nm |
20 |
25 Nm |
20 Nm
|
20 Nm
|
20 Nm
|
10 Nm |
25 |
35 Nm |
30 Nm
|
30 Nm
|
30 Nm
|
20 Nm |
30 |
50 Nm |
45 Nm
|
45 Nm
|
45 Nm
|
25 Nm |
|

Corrosion Resistance
Material |
Corrosion resistance in salt spray testing |
W1 |
Min. 72 h |
W2 |
Min. 72 h |
W4 |
Min. 240 h |
W5 |
Min. 400 h |
* Max.10% corrosion of the base material allowed, whereas at least 144 h without Fe-corrosion are required